Smart rules for regulation of temperature control have unified setting for switching between heating and cooling modes.
Info |
---|
Go to Settings → Virtual devices → Add virtual device → Multi-Value Switch section: Heating & Cooling. |
Define which modes are supported
...
In order to manage activation of heating or cooling within location, use predefined virtual multi-value switch Mode.
...
- To adjust Mode switch to show only modes that are relevant for specific location, use Service Settings of Mode multi-value switch.
- In Service Settings, open DEVICE tab and turn on/off specific modes.
...
Partial support for Mode is also in:
- Equithermic Equitherm regulation
- Blinds adjustment according to sun
...
Medium: HOT | Medium: COLD | |
---|---|---|
Heating Mode | Output actuator turns ON when | Output actuator is held in OFF state |
Cooling Mode | Output actuator is held in OFF state | Output actuator is turned on when |
Heating & Cooling Mode | Output actuator is turned on when | Output actuator is turned on when |
Off (No heating, no cooling) | Output actuator is held in OFF state | Output actuator is held in OFF state |
Example
Zone regulation of floor heating with hot water from boiler
Simple setup: Hot water is circulating in the pipes during heating season, and there is no circulation during cooling season (managed by boiler).
- Set Mode to "Fixed heating"
- Set Medium to "Hot (fixed)"
Automatic switching of Heating / Cooling modes
In order for the system to automatically switch the modes, add smart rule Equation for the multi-value switch Mode.
Example: