Medium:
HOT
Medium:
COLD
Heating
Mode

Output actuator turns (tick)ON when
desired temperature is higher than actual temperature

Output actuator is held in (error)OFF state
regardless of temperature

Cooling
Mode

Output actuator is held in (error)OFF state
regardless of temperature

Output actuator is turned on when
desired temperature is lower than actual temperature

Heating
& Cooling
Mode

Output actuator is turned on when
desired temperature is higher than actual temperature

Output actuator is turned on when
desired temperature is lower than actual temperature

Off
(No heating,
no cooling)

Output actuator is held in (error)OFF state
regardless of temperature

Output actuator is held in (error)OFF state
regardless of temperature

Example

Zone regulation of floor heating with hot water from boiler

...

In order for the system to automatically switch the modes, add smart rule Equation for the multi-value switch Mode.

Example:


Dynamic type medium workaround

If you use a machine (e.g. heat pump) that is able to produce both heating and cooling medium via the same output actuator, Dynamic type of medium is required for proper configuration. 

There are two possible scenario:

  1. Heat pump is in automatic mode and switches between hot and cold automaticaly by itself. TapHome just reads the reed contact with the actual type of medium.
  • Create reed contact input and use Device type "Heating & Cooling"

Image Added


Image Added


Image Added

  • Go to Thermostat and add "Temperature hysteresis controller" smar rule. In the smart rule use Heating & Cooling mode fixed and as Medium select reed contact prepared in previous step


Image Added


Image Added


Image Added


2. Heat pump is in manual mode and the TapHome switches between hot and cold using output relays that control auxillary inputs on heat pump.

  • Create virtual switch "Medium" and use "Heating & Cooling" device type within the service settings. 

Image Added


Image Added

  • Create the configuration where TapHome relays managing the type of medium on Heat Pump switch virtual switch "Medium" automatically from Cooling to Heating and viceversa. This will keep the Medium switch everytime in the right state (Heating or Cooling) in line with the heat pump.
  • Go to Thermostat and add "Temperature hysteresis controller" smar rule. In the smart rule use Heating & Cooling mode fixed and as Medium select switch Medium prepared in previous step.

Image Added


Image Added


Image Added