Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

doc_tap_Ppons;

doc_tap_defined_pipe;

Thermostat 

doc_tap_Thee;

doc_tap_Thee;

doc_tap_BoilerABC;

Boiler ABoiler BBoiler C

doc_tap_virtualAnalogOut;

...

doc_tap_OvOoot;

doc_tap_BasicConf;


doc_tap_SmartRuleTempPID;

...

doc_tap_1IDOO;doc_tap_1SRE;doc_tap_1ODB;
<1%doc_tap_01;doc_tap_001;
>1%

doc_tap_1Eq001;

doc_tap_1TrFaBoA;
>45%

doc_tap_1Eq045;n

doc_tap_1TrFaBoB;
>90%doc_tap_1Eq090;

doc_tap_1TrFaBoC;

...

doc_tap_boilersextracon;

doc_tap_BoilerPrior;


doc_tap_States_BoCAB;


doc_tap_SequencerABC;

doc_tap_InnDe;doc_tap_SmmRu;doc_tap_OuuDe;
doc_tap_Virtual_Push_butt;doc_tap_SeqABC;
(tick) doc
doc_tap_Rotseq;

doc_tap_BoPri;

...

doc_tap_2IDOO;doc_tap_2SRE;doc_tap_2ODB;doc_tap_2LCond;
<1%doc_tap_02;doc_tap_002;
>1%Equation:
If Overall Output > 0.01
TRUE: Turn on Boiler A
FALSE: Turn off Boiler A
Type: Multi-Value SwitchSmart Rule will only work if...
Boiler Priority is set to Priority A
doc_tap_2Eq01;

doc_tap_2TrFaBoA;doc_tap_2MultiPriorA;
>45%Equation:
If Overall Output > 0.45
TRUE: Turn on Boiler B
FALSE: Turn off Boiler B
Type: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority A
doc_tap_2Eq45;

doc_tap_2TrFaBoB;doc_tap_2MultiPriorAA;
>90%Equation:
If Overall Output > 0.90

TRUE: Turn on Boiler C
FALSE: Turn off Boiler C

Type: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority A
doc_tap_2Eq90;

doc_tap_2TrFaBoC;

doc_tap_2MultiPriorAAA;


doc_tap_SimilarLimitingBC;

doc_tap_3IDOO;doc_tap_3SRE;doc_tap_3ODB;doc_tap_3LCond;
<1%doc_tap_03;doc_tap_003;
>1%Equation:If Overall Output > 0.01
TRUE: Turn on Boiler B
FALSE: Turn off Boiler B
Type: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority B
doc_tap_3Eq01;

doc_tap_3TrFaBoB;doc_tap_3MultiPriorB;
>45%Equation:
If Overall Output > 0.45
TRUE: Turn on Boiler C
FALSE: Turn off Boiler C
Type: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority B
doc_tap_3Eq45;

doc_tap_3TrFaBoC;doc_tap_3MultiPriorBB;
>90%Equation:
If Overall Output > 0.90
TRUE: Turn on Boiler AFALSE: Turn off Boiler AType: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority B
doc_tap_3Eq90;

doc_tap_3TrFaBoA;

doc_tap_3MultiPriorBBB;


doc_tap_4IDOO;doc_tap_4SRE;doc_tap_4ODB;doc_tap_4LCond;
<1%doc_tap_04;doc_tap_004;
>1%Equation:If Overall Output > 0.01
TRUE: Turn on Boiler C
FALSE: Turn off Boiler C
Type: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority C
doc_tap_4Eq01;

doc_tap_4TrFaBoC;doc_tap_4MultiPriorC;
>45%Equation:
If Overall Output > 0.45
TRUE: Turn on Boiler A
FALSE: Turn off Boiler A
Type: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority C
doc_tap_4Eq45;

doc_tap_4TrFaBoA;doc_tap_4MultiPriorCC;
>90%Equation:
If Overall Output > 0.90

TRUE: Turn on Boiler B
FALSE: Turn off Boiler B

Type: Multi-Value Switch
Smart Rule will only work if...
Boiler Priority is set to Priority C
doc_tap_4Eq90;

doc_tap_4TrFaBoB;

doc_tap_4MultiPriorCCC;