doc_tap_notified;

Send notification when temperature exceeds 25 degrees

doc_tap_notification25deg;

Create virtual device (Menu → Settings → Virtual devices → + (or Add virtual device) → Switch

Set name "Notification"

Set device type = Emergency:

doc_tap_Create_Emerg;

Setting Emergency device type will automatically pre-define correct icons and names for On and Off states:

doc_tap_SettingEmerg;

Open details of this new virtual switch and select Add a new smart rule

doc_tap_Opendetails;

Select smart rule Equation

doc_tap_ruleEquation;

Set smart rule Equation to turn on your virtual emergency switch if the notification condition is met.
In our example, we are checking if one of temperatures (Temperature 1, Temperature 2) is higher than 25ºC. Also, once this condition is met, we set minimum duration to 30 minutes, so that we don't receive notifications too often.

doc_tap_EquationOften;

← EquationRename
doc_tap_Equation;doc_tap_Ren1;
SETTINGS   INFO   LIMITING CONDITION
doc_tap_sett_cond1;

Variables

Temperature 1
Temperature 2


Te = 21.8ºC
Te1 = 22.3ºC

doc_tap_VTT12;

Equation

(Te > 25) or (Te1 > 25)


doc_tap_EquationTe;

Actions

If result is TRUE, perform following actions:

Notification



On

doc_tap_ActNotific;doc_tap_ActOn;

If result is FALSE, perform following actions:

Notification


Off

doc_tap_Falsenotif;doc_tap_FalseOff;

Duration

When to stop performing specified actions

Minimum duration
Value: 30 minutes

Maximum duration
Value: not set



(tick)

(error)

doc_tap_Duration30min;

doc_tap_(/);

doc_tap_(X);

Open detail of device Notification and add smart rule "Notification"

doc_tap_OpenNotif;

Set smart rule Notification to provide proper feedback when temperatures are higher than 25 degrees:

doc_tap_SetNotif;

← NotificationRename
doc_tap_Notific;doc_tap_Ren2;
SETTINGS   INFO   LIMITING CONDITION
doc_tap_sett_cond2;

Send notifications when these sensors change:

Notification

+ Add sensor


doc_tap_NotifictSensor;

Notifications

Notify if turned on
Message: Temperatures higher than 25ºC

Notify if turned off
Message: Temperatures are OK


(tick)
 

(tick) 

doc_tap_NotificTempr25ºC;

doc_tap_(/);

doc_tap_(/);


There are more ways to setup push notifications:

  • Smart rule Device error notification sends notification always when one of specified devices is in error state
  • Smart rule Simple alarm sends push notification when there is a motion detected on one of specified sensors. It can be door/window magnet, or motion sensor
  • Smart rule Alarm can have push notification defined for each phase     doc_tap_DeviceSimpleAlarm;